Wire Gauge and Voltage Drop

Calculate the minimum wire size from current, run length, and allowed voltage drop. See actual V drop and W loss for copper or aluminum at 12/24/48 V

What this tool does

Size DC cables in seconds. Enter current, round-trip length, system voltage, allowed % drop, and conductor material. The tool outputs the minimum cross-section (mm² and approx. AWG), plus actual voltage drop and power loss for the selected size.

Inputs

  • Current (A)
  • Round-trip length (m) (out + back)
  • System voltage (V) — 12 / 24 / 48
  • Max voltage drop (%) — e.g., 3–5% for branches
  • Conductor — Copper or Aluminum

Outputs

  • Min cable size — mm² and approx. AWG
  • Voltage drop (V, % of system)
  • Power loss (W) at the entered load

How to use

  1. Enter A, round-trip meters, system V, max % drop, and material.
  2. Read the minimum mm² / AWG and the resulting V drop / W loss.
  3. If near limits or in hot runs, choose the next size up.

Example

Inputs: 30 A, 8 m round-trip, 12 V, 3% max, Copper Result (approx.):

  • Required ≥ 11.5 mm² → pick 16 mm² (≈ 5 AWG)
  • V drop ≈ 0.26 V (≈ 2.16%)
  • Loss ≈ 7.8 W

Notes & assumptions

  • Uses typical resistivity at ~20 °C. Heat and bundling increase drop.
  • Voltage-drop sizing doesn’t replace ampacity checks—always verify cable current rating and fusing.
  • Round-trip length is there and back. Don’t forget return path in chassis-grounded systems.

Why round-trip length?

Voltage drop happens on both out and return conductors.

What % drop should I use?

3% is common for critical loads. Up to 5% for non-critical branches.

Can I use aluminum in a van?

It works but needs larger sizes, proper terminations, and corrosion control. Copper is simpler for small systems.