Diesel Heater Size Calculator (2–5 kW)

Pick the right diesel heater size for your van from 2–5 kW using volume, insulation, and climate. Clear verdict plus heat-load estimate.

What this tool does

Size your diesel air heater the practical way. Enter van volume (or pick a preset), insulation, coldest outside and target inside temps, plus how you use heat (nights vs full-day). You’ll get an estimated heat load (W) and a recommended kW class (2 / 3 / 4–5 kW) with a plain-English verdict.

Inputs

  • Van size preset or interior volume (m³)
  • Insulation level — poor / decent / good
  • Coldest outside (°C) and target inside (°C)
  • Usage — nights only or full-day winter living

Outputs

  • Recommended heater size — 2 / 3 / 4–5 kW with range context
  • Estimated heat load (W / kW) at your worst case
  • Practical verdict — headroom vs short-cycling trade-offs
  • Quick takeaway — one-line summary for your scenario

Use it to avoid buying a heater that can’t catch up on cold nights or one that idles and soots all winter.

Example

  • Medium van (~11 m³), decent insulation
  • Outside −10 °C, inside 20 °C, full-day use

→ Load ≈ 3–4 kW → 4 kW class recommended with comfortable reserve.

Notes & limits

  • A simple planner — actual comfort varies with windows, drafts, altitude and install quality.
  • If you sit between sizes, most users prefer the larger unit with regular hot burns to avoid soot.
  • This tool sizes air heaters (Webasto/Autoterm/“diesel heater” style), not hydronic boilers.

How do I estimate my van’s interior volume (m³)?

Measure interior **length × width × average height** after furniture. Example: 3.2 m × 1.7 m × 2.0 m ≈ **10.9 m³**. Use a preset if you’re close; exact decimals aren’t needed.

Which insulation option should I pick?

Be conservative. Most DIY builds are **“decent”** (thermal bridges, windows). Pick **“good”** only if you’ve detailed bridges and glazing well; pick **“poor”** for minimal insulation.

Nights vs full-day — why does it change the result?

Full-day winter use adds runtime and recovery needs (doors opening, cold starts). The tool adds a buffer so the heater isn’t maxed out all day.

I’m between 3 kW and 4–5 kW — what now?

If you camp in **real cold**, work inside, or have lots of glass, go up a size and ensure you can run **hot burns** regularly. If you mostly do shoulder seasons, the smaller unit may be nicer (quieter, less idling).

Does altitude affect this sizing?

Yes. Higher altitude reduces oxygen and heater output. If you spend time above ~1,500–2,000 m, treat results as **optimistic** and consider the next size up or an altitude kit.