What this tool does
Helps you choose a proper DC fuse that protects the cable (not the device). Enter the circuit’s rated current, the wire cross-section, duty type, and fuse family; the tool returns a recommended fuse size (A), a compatible holder, and continuous-load derating guidance.
Inputs
- Circuit rated current (A) — expected continuous draw or branch rating
- Wire size — mm² (approx. AWG shown in the UI)
- Duty — Continuous (sustained) or Intermittent (short bursts)
- Fuse type — ANL, MEGA/MIDI, or ATO/ATC (blade)
Outputs
- Recommended fuse size (A) — rounds to the nearest available size without exceeding cable ampacity
- Holder type — ANL block, MEGA/MIDI holder, or inline blade holder
- Derating guidance — ~125% for continuous loads, ~100% for intermittent
How to use
- Enter circuit current (A) and wire size.
- Choose duty and fuse family you plan to install.
- Read the recommended amperage and holder; confirm it does not exceed the cable’s ampacity.
- If the needed fuse is higher than the cable allows, go up a wire size or lower the circuit draw.
Example
- Circuit current: 38 A (fridge + fans branch)
- Wire: 6 mm² (≈ 9.5 AWG), ampacity ≈ 38 A
- Duty: Continuous → target fuse = 38 A × 1.25 ≈ 47.5 A
- Fuse family: MEGA/MIDI → available sizes: 40, 50, 60, …
Result:
- Candidate = 50 A, but cable max fuse ≈ 38–40 A → recommend 40 A.
- Holder: MEGA/MIDI holder near the source.
- If nuisance blows occur, increase cable size and re-select a higher fuse, never exceed cable limits.
Notes & best practices
- Protect the smallest conductor in the run (including pigtails and device leads).
- Place the fuse close to the source (battery/bus) to minimize unprotected length.
- Warm compartments and bundled looms reduce ampacity — be conservative.
- For inverters/chargers, check manufacturer specs for surge and recommended fuse size.
- Choose quality holders with low contact resistance; torque and re-check periodically.